MegaPoints Controllers

System2 · User reference

OUT-64

Drives up to 64 colour addressable WS2812B LEDs in your mimic panel, and brings your scenery to life with sixteen built-in lighting effects.

All the convenience of Wi-Fi configuration with a robust, bullet-proof, two wire CAN bus network.

Revision 6 · 23 November 2026 · For software version 30, with the December 2026 update

System2 OUT-64 board

Using your OUT-64

Start with one LED, make it do one useful job, then build up the rest of the layout. This walkthrough brings the wiring, screen settings, lighting examples, testing and saving into one place.

The screenshots show the version 27 configuration interface with demonstration settings. They illustrate what to enter; they are not photographs of a connected layout. Select a screenshot to enlarge it.

Choose what this board will do

You want to…UseWhat it controls
Show points, routes or occupied track on a panelMimic PanelIndividual LEDs, using messages from switches, sensors or other System2 boards.
Light a pub, fire, workshop, street or other scenic featureLighting Effects, with Mood Lighting offUp to eight effect slots. Each selects one output and a run of LEDs. Other LEDs remain available for panel indications.
Cycle overhead layout lighting between day and nightMood LightingOutput 1 takes over the whole board. Outputs 2–4 go dark and the panel indications and eight scenic slots stop displaying.

In the examples below, L1 / Ch 1 is reserved for panel indications and L2 / Ch 2 is used for scenery. L3 and L4 remain free. A channel is simply the output connector number: Ch 2 means connector L2.

1. Connect a string and open the board

  1. With power off, connect a compatible WS2812B addressable LED string to L1 for a panel indication, or L2 for the lighting examples. Follow the connection diagram: white left, red centre, black right.
  2. Supply the board with regulated 12 V DC, at least 1 A, using the top two terminals of the green connector. These power terminals accept either polarity. The lower terminals are CAN-H and CAN-L. See Connecting the board for the complete hookup.
  3. Join the board to your Wi-Fi. MegaConsole's Start here is the simplest way; without a PC, use the board's own Wi-Fi and its set-up page at 4.3.2.1/wifimanager.html. Both are described in the Wi-Fi setup instructions. Then open its configuration page in your browser using its address or the device name on its label.
  4. Use the Mimic Panel or Lighting Effects section heading to open the controls you need. Leave Mood Lighting unticked for both of the following examples.

LED numbers start at the board end of each string. The first LED on L2 is Ch 2, LED 1; the next is Ch 2, LED 2. Every normal output has positions 1–16. A scenic slot can use one position, several consecutive positions or all sixteen.

2. Make one panel LED respond to a switch

A vPort is the number shared by a control and the thing it operates. For this example use an unused vPort, such as 101, for both the sending switch and the OUT-64 LED.

  1. On the Panel Controller, configure your switch to send vPort 101 using a maintained switch or stateful control. This example needs an on/off state, not a stateless pushbutton press.
  2. On the OUT-64, open Mimic Panel. In row 1, under BG 1, enter 101 and choose green. BG 1 is the background indication for output L1.
  3. Leave that row's Inv unticked and FG 1 at 0. Move out of the entry box to send the change.
  4. Operate the switch. LED 1 on L1 should be green while vPort 101 is on and dark while it is off. The two boards must share the same working CAN or MQTT control network.
  5. Select Save Changes on the OUT-64 and save the sending controller's settings too.
Example: the first rows of output 1. BG 1, row 1 listens to vPort 101 and uses green; FG 1 is unused. Select to enlarge.

BG and FG: background shows the normal indication. An active foreground indication replaces it, for example red occupancy over a white route. To make an LED permanently on, use BG vPort 0 with Inv ticked. Keep scenic effects away from these LEDs unless you deliberately want the effect to hide the indication.

3. Make your first lighting effect

This example lights a television inside a pub using LED 1 on L2. It runs by itself, so no switch, trigger message or sending board is needed.

  1. Open Lighting Effects. Tick Effects running. Leave Mood Lighting off.
  2. In the first row, enter Pub TV as the Name and set Ch = 2, From = 1 and To = 1.
  3. Choose Television from Effect. Tick the row's On box and choose Always under When. Trigger is greyed out because Always does not use it.
  4. Start with Bright around three-fifths, Speed in the middle and Depth just over the middle. Leave Base and Accent black to use the built-in colours. These slider positions are starting points, not values that must be exact.
  5. Tick Full-range effects for smoother low-level lighting, then set the effect's own Bright slider to suit the model. This gives effects the full output range; it can make them brighter than with the box unticked.
  6. Look at the real LED. Put it inside the building, aimed at an inside wall or diffuser. Use Test to help identify the chosen LED, then judge its normal appearance after the two-second test ends.
  7. Select Save Changes below the main sections.
The Lighting Effects controls with the first Pub TV example entered. Effects running and Full-range effects are ticked; Mood Lighting is off. Select to enlarge.

Preview is an illustration, not a status lamp. It can animate even when a slot is unticked or its real-world trigger is off. An unticked slot is shown dimmed. Check the real LEDs to confirm the result.

4. Read a lighting row from left to right

ControlHow to use it
On / NameTick On to enable the slot. Untick it to stop that slot while keeping its settings. Give it a recognisable name of up to 16 characters.
Ch / From / ToChoose output 1–4 and the first and last LED, each 1–16. Both ends are included: From 2 to To 4 uses three LEDs. Setting From higher than To reverses the effect along the run.
EffectChoose the animation. Selecting (none) produces no scenic effect.
BrightThe slot's brightness ceiling, from 0 to 255. Zero is dark. The animated light can fall below the ceiling.
Speed / DepthEach runs from 0 to 100. Speed changes the timing or behaviour; 50 is the normal starting point. Depth changes how strongly the effect varies. A slower effect and a subtler effect are different adjustments.
Base / AccentOptional colour overrides. Black means “use this effect's built-in colour”, not “switch it off”. Accent supplies a second colour where the chosen effect uses one.
Trigger / WhenWhen decides whether the slot runs continuously, follows an on/off control, runs a short burst or follows real dusk and dawn. Trigger supplies the vPort for the two externally controlled modes.
Preview / TestPreview is an indicative browser animation. Test runs the selected effect on its real LED range for two seconds, using maximum slot brightness. It bypasses the row's On and When conditions, but requires Effects running and does not bypass Mood Lighting. With Full-range effects off, the main Brightness setting still limits the output.

Two brightness controls: with Full-range effects off, the main Brightness slider also limits the effects. With it on, the main slider continues to set panel brightness in software while each effect uses its own Bright setting. Full-range effects is off by default.

5. Build a small scene on one string

Once the pub works, add the following rows. They use all sixteen LEDs of L2 without overlaps. L1 stays available for your panel; L3 and L4 are still unused. Use spare vPort numbers in your own layout—41 and 42 below are examples.

Row / nameChFrom–ToEffectWhenTrigger
1 · Pub TV21–1TelevisionAlwaysUnused
2 · Signal box fire22–4Coal fire / brazierAlwaysUnused
3 · Shed welding25–5Electric arc weldingWhile on41
4 · Street lamps26–10Dusk to dawn lampDusk -> dawnUnused
5 · Passing train211–16Passing trainOne shot42

Tick On for rows 1–5 and leave rows 6–8 unticked. Start with Bright around three-fifths to two-thirds, Speed in the middle and Depth around the middle. The two screenshots below show the same rows, split into left and right portions so the controls are readable.

Left side: name each scene, choose its output and LED range, then choose its effect and tune the three sliders. Select to enlarge.
Right side, in the same row order: colours, trigger number, When mode, Preview and Test. Only the welding and passing-train rows use a Trigger. Select to enlarge.

A fire that runs continuously

Put LEDs 2–4 behind the fire grate or a diffuser. Use the second row above, with Coal fire / brazier and Always. Adjust Bright until the effect fits the scene. Depth changes the activity of the fire. If its movement appears to travel the wrong way along the LEDs, swap From and To to 4 and 2.

Welding controlled by a switch

  1. Configure a spare switch on your sending board to send vPort 41 as an on/off state.
  2. On the OUT-64, set the Shed welding row to Trigger 41 and While on.
  3. Turn the switch on: LED 5 produces welding flashes. Turn it off: that effect stops. If nothing happens, check the shared CAN or MQTT network and that both devices use the same vPort.

A stateless pushbutton press is not a held on/off state. Use a maintained or stateful control for While on. Use One shot for a pushbutton burst.

Street lamps at real dusk

For LEDs 6–10, choose both Effect = Dusk to dawn lamp and When = Dusk -> dawn. These are separate choices: the Effect provides the lamp's warm-up and fade, while When supplies the daylight schedule.

The board needs a working clock and recognised time zone. Internet access gives it the time of day. From version 30 it takes your time zone from the computer or phone you open its page on, so open the page once after an update; until then the dusk-to-dawn lamps stay on. From the December 2026 update (version 31) it also takes the time zone from MegaConsole, or from another board on the System2 cable, and keeps it, and a time zone set on the board's own page still wins. A board with no internet then takes the time of day from another board on the cable that has it, or from MegaConsole. Sunset and sunrise are estimated from the time zone's representative location and follow seasonal and clock changes. If the clock or location is unavailable, the board treats it as night and leaves the effect active.

To check the wiring during daylight, use Test. For a longer trial, temporarily set When to Always; return it to Dusk -> dawn before saving. The browser preview compresses the day/night cycle, so it is not evidence that the board considers it night.

A passing train started by a pushbutton

  1. Configure a Panel Controller pushbutton to send an unused vPort, 42 in this example.
  2. Set the fifth row to Passing train, Trigger 42 and One shot, covering LEDs 11–16.
  3. Press the button. The effect runs for approximately six seconds, then stops. Pressing again restarts the burst. An off-to-on change from a switch can also start it.
  4. If the light appears to move in the wrong direction, use From 16, To 11.

For a platform camera-flash scene, the same trigger arrangement works with Camera flashes. It produces a short animated burst, not a promise of exactly one flash.

6. Choose the right trigger mode

WhenChoose it forWhat must happen
AlwaysA pub television, candle, fire or water reflectionThe slot is enabled and Effects running is ticked. Trigger is ignored and greyed out.
While onA workshop switch, crossing control or active sensorThe selected trigger vPort must be on. Off stops the effect.
One shotA pushbutton-operated passing train or flash sceneA stateless press or a transition to on starts a six-second run. Repeated triggers restart the run.
Dusk -> dawnStreet lamps or town windows on real night-time hoursThe board's clock and time-zone calculation decide when it is dark. Trigger is ignored and greyed out.

7. Keep scenery and panel indications separate

An active effect replaces panel colours on every LED in its range. When the effect stops, those LEDs return to the current panel state. The interface warns when an effect's range overlaps panel cells with a vPort assigned.

Use non-overlapping ranges for scenic slots too. If two active slots share an LED, the lower row in the table is drawn last and wins. That is not a useful starting point for commissioning. Keep a simple allocation list like the scene table above, and add one row at a time.

Before installing LEDs permanently, use a one-LED range and Test to identify each position. Aim scenic LEDs at a surface inside the model and diffuse them; a bare LED facing the viewer seldom gives the best result.

8. Use Mood Lighting for an overhead day/night cycle

Mood Lighting is a separate whole-board mode. It is not a ninth scenic slot and it does not follow the real clock. It repeatedly changes an Output 1 run from blue night lighting to warm daylight and back.

  1. For an initial trial, use a standard 16-LED run on L1. Check the strip and power arrangement before using a longer run.
  2. Open Lighting Effects. Set LEDs on Output 1 to the actual number on the run, from 16 to 350.
  3. Tick Mood Lighting. It starts at night, holds for 45 seconds, then fades to day over 15 seconds. Day holds for 45 seconds and then fades to night over 15 seconds. A complete night/day cycle takes two minutes.
  4. Untick Mood Lighting to return to the panel indications and the eight scenic slots. Their settings are kept and the board continues following incoming control messages while Mood Lighting runs.
  5. Select Save Changes if you want the mode and LED count retained after a restart.
Mood Lighting enabled for a 16-LED Output 1 run. The interface explains that this mode takes over the board. Select to enlarge.

While this mode runs, Outputs 2–4 are dark and the scenic slots do not display. The main Brightness slider does not dim Mood Lighting. A long strip at daylight needs much more power than the board's own supply: the interface quotes around 20 A for 350 LEDs at full white. Do not assume the board can supply that load; use a correctly designed power arrangement for the strip.

9. Save, check and keep a backup

  1. Adjustments take effect as you change a control and leave the field; they are not automatically permanent.
  2. Select the green Save Changes button below the main sections. Wait for the board's status log to confirm the save.
  3. When it is convenient, restart the board and check that the intended settings and behaviour return. Operate the sending controls again for triggered examples.
  4. Use Backup on the configuration page to keep a settings copy before making a large change.
  5. From version 29 there is also Cloud Backup: Backup Now, an automatic copy after every Save or update, and restore from any of your cloud copies. The automatic copy is sent by the board's page or by MegaConsole, whichever is running.
Save Changes keeps the settings on the board. Reload Values discards unsaved edits; Reset to Defaults clears the configuration. Select to enlarge.

10. If the effect does not behave as expected

What you seeWhat to check
All scenic effects are darkEffects running must be ticked and Mood Lighting off. Check the row's On box, selected Effect, Ch and range. Bright must be above zero. With Full-range effects off, check the main Brightness too.
Preview moves but the real LED does notPreview is not live feedback. Use Test, check wiring and channel, then check When and the trigger state.
Test works but the switch does nothingUse While on for a maintained state or One shot for a press. Check the trigger vPort on both boards and the control network. After changing the trigger number, operate the control again.
Test is disabledTick Effects running. A working Test button still cannot make a scenic slot display while Mood Lighting owns the board.
The wrong LED changes, or an indication disappearsCh selects the physical connector; From and To select positions on that string. Check the overlap warning, other active slots and your allocation list.
Street lamps stay on during the dayCheck When is Dusk -> dawn and that the board has obtained its clock and time zone. With missing clock/location information it deliberately behaves as though it is night. After an update, open the board's page once so it takes your time zone.
Colours look wrong or an effect is too harshReturn Base and Accent to black for the built-in palette. Reduce Bright or Depth, then diffuse the LED. Full-range effects can improve smoothness.
Settings disappear after restartingUse Save Changes and check the save confirmation. Leaving a field updates the running board but does not replace the save step.

Choose from the sixteen scenic effects

The effect decides the appearance; When decides when it runs. The combinations below are useful starting points, not fixed restrictions.

EffectA useful sceneStarting mode
TelevisionChanging light behind a pub or house windowAlways
Electric arc weldingBlue-white workshop flashes and a warm afterglowWhile on
Candle / oil lampWarm flicker in a hut or roomAlways
Coal fire / brazierGlowing coals in a signal box, forge or brazierAlways
Fluorescent tubeA workshop tube striking and settlingWhile on
Lightning stormA storm behind scenery or through a sky diffuserOne shot or Always
Rotating beaconA sweeping beacon or lighthouseAlways
Level crossingAlternating groups of crossing lampsWhile on
Dusk to dawn lampStreet lights with warm-up and fadeDusk -> dawn
Loco fireboxA firebox glow with brighter flaresAlways
Town windowsRooms switching on and off at different timesDusk -> dawn
Passing trainMoving carriage-window light along a runOne shot
Camera flashesPhotographers on a platformOne shot
Neon, failing tubeA flickering sign or unreliable lightAlways
Water reflectionsLight moving beneath a canal or harbour sceneAlways
Emergency bluesAlternating emergency-vehicle flashesWhile on

Once the practical examples work, use the detailed reference sections below for additional panel arrangements, networking, updates and recovery.

Documentation revisions

This document is for Output-64 software version 20 or later. If your board has access to the Internet it will tell you when a new version is available. See Update firmware for details.

RevisionDateWhat changed
623 November 2026Wi-Fi set-up address updated (4.3.2.1/wifimanager.html); MegaConsole set-up; features to version 30 and the December 2026 update (version 31).
HTML updateSeptember 2026Added a single practical walkthrough, configuration screenshots, lighting recipes, Mood Lighting, testing and saving instructions. The examples use one consistent output allocation.
5August 2026Rewritten for software version 20. Adds Scenic lighting effects, the new Software Update page with roll back and the pre-release channel, board recovery, the dashboard charts, product registration, the storage upgrade and the rebuilt CAN Network Monitor. Board photographs replaced with the current V1.4 board, and the connection diagram relabelled. Reset to defaults and CAN ID behaviour corrected for this product.
4August 2026First issue for the Output-64.

What is System2 Air?

System2 is our generation of model railway accessory bus products that feature our V-Port protocol (virtual port) and can address up to 60,000 devices. You can scale an installation from a single Servo- 8 Controller (8 vPorts) right up to a huge layout as your needs grow. Flexibility is baked in, and as we announce new modules they work right alongside your existing System2 modules.

The "Air" in System2 refers to how you configure the system. It is done wirelessly using Wi-Fi. This means you can configure a device using your PC, tablet or phone, and it replaces the need for buttons, flashing lights and extension cables to reach under baseboard locations.

We use Wi-Fi for configuration and a CAN network for data. This offers high speed, low latency and above all else reliability. You can even shut down the Wi-Fi network when your configuration is complete, making your system secure and robust. It is not required for operation at all.

Software for all System2 Air modules can be updated over the air if your network allows Internet access. A single button push is all that is needed to download and install the latest version, and from software version 18 you can also roll back to the previous version from the same page if you change your mind. This means that as new ideas and features are introduced everyone gets to benefit from them. You can see the changes that have been introduced since your last update and choose whether to install or not. You will not get nagging reminders to update. It is flexible and entirely up to you when, or if, you decide to do it.

System2 has been real world tested on some of the largest exhibition model railway layouts in the UK, so you can be confident it is fit for your needs and fit for purpose.

Each of our System2 boards has the administrative core baked in. You can connect to any board's admin web page and from there manage your entire network. There is no central point of control (or failure) as they are all peers in their own right.

We use standard web protocols for configuration so that your browser can connect and perform all administrative tasks without requiring any special apps and app permissions. This leaves you in control of your network.

System2 Air: for the smallest to the largest layouts and everything in between.

In order to use System2 you will need a Wi-Fi router configured for DHCP with optional Internet access. This is the standard router configuration as supplied by your Internet Service Provider.

Designed and manufactured in Cheshire, England.

How to use this document

Treat this guide as a reference. All settings are documented and examples are given where appropriate. You do not need to read it from front to back: the Mimic panel display chapter covers everything to do with showing track and signals, and the Scenic lighting effects chapter is entirely self-contained.

If you are setting a board up for the very first time, start at Connecting the board, then Getting your first board on your Wi-Fi.

Caution

This is a 12 Volt device and should be connected to a regulated power supply of at least 1 Amp.

  • Do NOT connect any part of this device directly to your track bus.
  • MegaPoints Controllers use static sensitive components that must be handled with care. Avoid touching any components or the printed circuit on the bottom of the board.
  • Avoid placing the board on any metallic surface, including track.
  • Treat the LED connectors with the care you would any scale locomotive. Do not twist or apply sideways pressure to the socket.
  • Remove a cable by gripping the leads and pulling straight out, perpendicular to the board.
  • Do not force any of the miniature connectors.

What is new in software version 20

If you are coming from an earlier Output-64, or from the Revision 4 guide, this is what has been added. Each item has its own section later in this document.

FeatureWhat it gives you
Scenic lighting effectsSixteen animated effects in eight independent slots, layered on top of the mimic panel display: television, coal fire, arc welding, dusk to dawn street lamps and more.
A real clockThe board works out its own time zone, keeps time and follows the summer time changes on its own. This is what makes the Dusk to dawn effect mode possible.
Roll backReturn to the previously installed software version from the board's own Software Update page, without any special tools.
Pre-release channelAn optional switch that offers you new versions early, if you would like to try them.
RecoveryHold the Hotspot button for 10 seconds while the board starts and it will fetch a known good copy of its software and install it.
Dashboard chartsShow Charts plots the Wi-Fi signal strength and CAN traffic over time, so a marginal aerial position is visible rather than guessed at.
Product registrationRegister the board to yourself from its own page, so support and warranty enquiries know the board.
Settings backup and restoreThe whole configuration can be captured and put back by MegaConsole, which is useful before an experiment or when replacing a board.
Rebuilt CAN Network MonitorThe network monitor is now a shared, maintained component with a cleaner display.
Fleet reportingThe board answers questions about the whole network, so Locate Board reports name, location, address and version for every board on the bus.
New storage layoutMore room inside the board for software and settings, and a filesystem that copes better with power cuts. Version 20 performs this upgrade for you.
ReliabilityThe board's own web pages now load reliably every time, the CAN controller recovers itself from a bus fault, and an out of range CAN ID is repaired at start up.

For the releases since version 20, including the December 2026 update, see Appendix A: Software release notes.

System2 Output-64

Introduction

The System2 Output-64 supports up to 64 colour addressable LEDs in four strings of 16 LEDs each.

Each LED is configured in software. What an LED does is not constrained by where it sits in the string, so you are free to wire the panel in whatever order is convenient and sort it out afterwards on screen.

The Output-64 is perfectly matched with the IN-32 as well as the Panel Controller, Mini Panel Controller and Route Processor, and will provide a full colour display for your mimic panel.

The Output-64 has the following use cases:

  • Single LED ON and OFF at any colour.
  • Switching an LED pair ON and OFF to indicate turnout position.
  • Illuminating a whole road so a set route lights up end to end.
  • Indicating and superimposing block occupancy in conjunction with block data.
  • Indicating the power state of a DCC section.
  • Providing in-building adjustable lighting that can be triggered by button, switch or layout event.
  • Sixteen animated scenic lighting effects, from a flickering television to a dusk to dawn street lamp.
  • Having a bespoke colour set from a Panel Controller or OUT-32 board.

Connecting the board

Everything you need to connect is on the two edges of the board. The four LED strings are along the top right, and the single green terminal block carries both the power and the network.

Connecting the board illustration

Output-64 connections (board V1.4)

ConnectorPurpose
L1 to L4The four LED string outputs. Each drives up to 16 WS2812B addressable LEDs, numbered 1 to 16 from the board outwards.
Green terminal, top twoPower in. 12V DC regulated, 1 Amp minimum. Either polarity: the board rectifies it for you, so it does not matter which way round you connect it.
Green terminal, thirdCAN-H. Observe polarity: CAN-H must go to CAN-H on every board.
Green terminal, fourth (bottom)CAN-L. Observe polarity: CAN-L must go to CAN-L on every board.
TERM jumperNetwork termination. Fit on the first and last board of the network only, a maximum of two per network.
HOTSPOT buttonHold for 1 second to start the board's own Wi-Fi hotspot for configuration. Hold for 10 seconds while the board is starting to enter recovery.
RUN LED (green)Flashes about once a second in normal running. It flashes at double rate when the hotspot is active, faster still when you have asked the board to identify itself, and erratically while software is being downloaded.
PWR LED (orange)Lit whenever 12V is present.
LabelThe device name and serial number, for example out64-73f0ce.

LED outputs (x4) and type

The Output-64 drives WS2812B addressable LEDs. Current boards are fitted with servo type connectors:

Four separate rows L1 to L4, three pins across each. White wire left, red centre, black right. One three-pin plug per LED string.
Use the same wire order on L1, L2, L3 and L4: white left, red centre, black right.

Earlier boards were fitted with micro JST connectors, which have now been phased out in favour of the servo type. On those boards the pins are centre positive, right negative and left signal.

Pre-wired test RGB LED strips are available from our web shop.

Take care. Do not twist or apply any angular force when removing an LED cable. Grip the cable and pull it straight out, perpendicular to the board.

Power

Apply 12V DC from a regulated supply of at least 1 Amp to the top two terminals of the green connector. Polarity does not matter.

Sixty-four LEDs at full white are a real load. If you are running long strings at high brightness, allow more supply headroom and keep the Brightness setting in mind: it limits current as well as glare, and a mimic panel almost always looks better turned down.

Network

The CAN network uses the lower two terminals of the same green connector. Use twisted pair signal cable and make sure CAN-H goes to CAN-H and CAN-L goes to CAN-L on every board. Fit the termination jumper on the first and last board only.

First use

Connect a test LED strip to L1, apply 12V and watch the RUN LED begin to flash about once a second. First time boot can take up to 30 seconds.

Then follow Getting your first board on your Wi-Fi to bring the board onto your network, after which everything else in this guide is done from your browser.

Mimic panel display

This chapter covers the main grid on the board's web page: the part that shows turnouts, routes, block occupancy and district power. Scenic lighting effects are covered in their own chapter and sit on top of everything here.

For the examples we assume a test LED strip is attached to String 1 and String 2, connecting 32 LEDs, and that a Panel Controller is configured either as a toggle switch or a stateful switch type. Driving the LEDs from a pushbutton is a good way to get started; see Indicating useful information at the end of this chapter for how to read your track for real.

New in version 27. A point or signal that is on the move flashes its cell until it arrives, as it does on a Panel Controller, and stops after ten seconds if the arrival is never reported.

New in version 28. A brand-new board lights its LEDs straight away: LEDs 1 to 64 follow V-Ports 1 to 64, output 1's sixteen LEDs first. Boards already set up keep their settings.

Foreground and background colours explained

Foreground and background colours explained illustration

The background colour (BG) column shows normal information such as turnout position, switch activation or the state of some other monitored device on the layout. These are set as ON/OFF, with white being the default colour.

The foreground colour is an override that will replace any displayed background colour if it is set. This is useful when you have a route illuminated in white with a red occupied block on top of it. When the foreground colour is switched off, the background colour will be displayed again if it is still enabled.

ON / OFF single LED

This is an indicator for a single LED on and off. We will assign the vPort to 1 and drive it from a Panel Controller, though it can be driven from a Route Processor, DCC module or track sensor.

Enter vPort 1 in the BG 1 column for the top position (LED #1) and TAB or click out of the box to save, with the Panel Controller set to any switch type other than "stateless" and "start of day".

Pressing the button will toggle the LED on and off with the default colour of white.

ON / OFF LED pair

ON / OFF LED pair illustration

Building on the previous example, we will use a pair of LEDs to indicate points position, similar to the standard green/green LED cable pair used in the System2 Mini Panel and Panel Controllers.

Set the BG1 LED #1 to vPort 1 and the second LED also to vPort 1. If you are tempted to press the button now you will have the most useless points indicator ever, as they will both come on and off at the same time. We will leverage this later to great use.

ON / OFF LED pair illustration

On LED #1 tick the "Inv" box. Pressing the button shows they are now working as a complementary pair and indicate the chosen points direction. If you need to reverse the logic, swap the "Inv" ticks.

Let us go green. On the dropdown selector for the first two LEDs select green for both. You now have green LEDs, or whatever colour you chose.

Route indication

We can develop the points position idea further by lighting the entire road so that it illuminates when selected. Refer to the diagram below. The blue road diverges from the black main line. The numbers in the circles refer to the string and LED position; these are all on string 1.

Route indication illustration
  • Set LEDs 3 to 10 to vPort 2.
  • Set LEDs 7 to 10 Inverted.

Operating the button or switch on vPort 2 will now switch the roads so that one or the other is illuminated.

The first two LEDs on the black line look left out. We will set these to be always on by inverting them and not setting a vPort.

  • Set LEDs 1 to 2 Inverted (vPort should be either 0 or blank).

If all that white is too bright, adjust it with the Brightness slider.

We now have roads illuminated to show which direction the points are set, and we have used a single vPort (2) to set the entire display.

Block occupancy

Block occupancy illustration

Building on the previous example, let us assume every LED is connected to a block detector and each LED represents one block. We need to see where our trains are. In this example we will use the buttons or switches to simulate the block detector, so there is no need to track wire the example.

Add the corresponding FG vPorts, shown in red numbering in the diagram above.

Operate each of the block vPorts in turn (3 to 12) and observe the red block occupied indicator as it travels down the line. Occupied blocks will return to white when the blocks clear. You can have occupied track in an unselected road; those will return to off when the blocks clear.

Leave the settings from the previous example unchanged, we will be building on them.

Always ON LED

In the route indication example we set LEDs 1 and 2 Inverted with a blank or 0 vPort.

  • The blank vPort means it can never be selected.
  • Inverting it means it is always on.

This provides the facility to leave LEDs permanently on if desired.

DCC power monitor

DCC power monitor illustration

On a well known layout we have implemented an eight district power monitor. This indicates on all four mimic panels the state of the DCC power for that section, using green for OK and red for power fail.

It is easy to configure using one vPort per power district. Follow the steps below to create an example power monitor. First, clear out the previous settings by:

  • Reset to defaults
  • Save Changes
  • Reboot

For each LED on string 1, LEDs 1 to 8, set the following:

LEDBG vPortBG invertBG colourFG vPortFG colour
1-10YESRED1GREEN
1-20YESRED2GREEN
1-30YESRED3GREEN
1-40YESRED4GREEN
1-50YESRED5GREEN
1-60YESRED6GREEN
1-70YESRED7GREEN
1-80YESRED8GREEN

Your settings should look like this:

DCC power monitor illustration

You should now have all red LEDs indicating power failure, which is the default state. Switch on any of the vPorts 1 to 8 and that indicator will change to green, simulating track power.

In place of the switches, connect a Points Position Indicator to the input terminal of the Panel Controller and the sense wires across the DCC bus. It will go green when power is detected.

Panel Controller colour override

The Panel Controller and Mini Panel Controller have the ability to override any colour when used via the CAN network. This feature is not available via MQTT.

Reset the Output-64 to its default state with Reset to defaults, Save Changes and Reboot. Then set LED 1 to vPort 1 for the BG1 column, switch it on, and observe the white foreground colour.

From the Panel Controller config screen set the following RGB values for vPort 1: Red 255, Green 0, Blue 255. When the button is turned on you will see the chosen colour displayed on the LED.

Each individual Panel Controller input can have its own colour override if desired.

Custom colours

Every dropdown offers eight colours: White, Red, Blue, Green, Yellow and three custom colours. The three custom colours are defined in the Custom Colours section just above the Brightness slider, as red, green and blue values from 0 to 255. Name them if you like; the name is only there to help you remember what the colour is for.

Brightness

The Brightness slider sets the overall level for the whole board. A mimic panel that looks right in a bright room is usually far too bright at an exhibition, and turning it down also reduces the current drawn from your supply.

If you are using lighting effects, consider ticking Full-range effects as well. That runs the LED driver at full scale and applies your Brightness setting in software, which gives the effects all 256 levels to work with instead of about 50. Your panel colours are unchanged.

Indicating useful information

The examples above provide a flavour of what is possible. In practice the useful sources are the Points Position Indicator for turnout position, block detectors for occupancy, and the Panel Controller or Route Processor for anything you set by hand. Anything that can set a vPort can drive an LED here.

Network cabling

Network cabling illustration

All cables should be twisted pair signal cable. You can use droppers to a main bus, much like DCC, or connect boards to each other in daisy chain fashion. Ensure CAN-H and CAN-L connect to the same terminal in all cases.

Fit the termination jumpers to the first and last board on your network if they are not already fitted. The jumpers may have been pre-installed on all boards; remove all except the first and last System2 boards on the network, for a maximum of two jumpers per network.

Getting your first board on your Wi-Fi

The simplest way: MegaConsole

MegaConsole is the simplest way to get a System2 board on your network and set up. It is MegaPoints' free program for a Windows 10 or 11 PC: get it from megapointscontrollers.co.uk/megaconsole. Start here is the first item on its menu, and new users also see a "New to System2? Start here" card on its Home page.

A worked example: a new mimic panel with a Panel Controller for the switches, two Servo-8s for the points and an Output-64 for the panel LEDs, all joined by the System2 cable.

  1. Switch the boards on and run MegaConsole on a laptop near them. Choose Start here, then A new layout, then Start.
  2. MegaConsole lists every board it can see. The new Output-64 is waiting on its own Wi-Fi, named like out64-73f0ce, the name on its label. Tick it and the other boards.
  3. Choose Along the cable (wired), so the panel keeps working with the PC switched off. Pick your Wi-Fi network and type its password. MegaConsole checks the password itself before any board is touched.
  4. For the switches and points, choose Number them for me. MegaConsole matches switch 1 to point 1 and so on, keeping clear of numbers your working boards already use.
  5. Press Set up my boards. MegaConsole gives the waiting boards your Wi-Fi, and as soon as one board is on your Wi-Fi it sends the details along the System2 cable, so the rest join at once. It then updates any board that needs it, checks that no two boards share numbers and takes a backup.
  6. Press Save my setup sheet. It lists every switch and point with its vPort number. On the Output-64, open Mimic Panel and enter each point's number as the BG vPort of the LED that shows it (see Make one panel LED respond to a switch). Take me to my boards opens the Output-64's page.

The Output-64 picks up Wi-Fi details sent along the cable only when your network name and password are each 19 characters or fewer. If either is longer, give the Output-64 your Wi-Fi through its own Wi-Fi, as below.

The PC needs Wi-Fi of its own (every laptop has it) and must be near the boards. On Windows 11, if MegaConsole cannot see any Wi-Fi networks, turn on Settings > Privacy & security > Location, including "Let desktop apps access your location". Keep a System2 Programmer and CAN Adaptor to hand: with the CAN Adaptor plugged into the PC, MegaConsole reaches boards along the System2 cable without waiting on Wi-Fi, and the Programmer puts right a board that will not answer at all. MegaConsole's user guide covers every step in section 6.15, "Set up your boards with Start here".

No PC? Use the board's own Wi-Fi

The very first board of your System2 Air network should be configured for your Wi-Fi. This will allow you to connect and adjust the board settings, download future software updates and change port addresses. Broadly speaking, here is how to connect to your Wi-Fi:

  • Apply 12V DC regulated power to the board.
  • Observe the RUN LED flashing about once per second. This may take up to 30 seconds on a first time boot.
  • A new board, or one with no Wi-Fi details, puts up its own Wi-Fi by itself. Otherwise, hold the HOTSPOT button for 1 second; observe the RUN LED flash rate increase to double.
  • From your phone, tablet or other Wi-Fi device, scan for Wi-Fi networks and locate the hotspot for the board. It will be the device name and serial number on the label, such as "out64-73f0ce". It has no password.
  • Connect to this hotspot network. You may receive a warning stating this network does not connect to the Internet. This is OK.
  • In your browser, go to 4.3.2.1/wifimanager.html. No page opens by itself.
  • Press the "Scan WiFi" button. After a few seconds the adjacent box will populate with scanned networks. Select the appropriate network; the strongest signals are towards the top.
  • Enter the password, noting case sensitivity, and press the save button. For a hidden network, type its name and password under Enter Wi-Fi details manually instead.
  • Press Reboot. Rejoin your normal Wi-Fi, then open the board by its name, for example "out64-73f0ce.local" (see Use the device name to connect), or from MegaConsole.
Getting your first board on your Wi-Fi illustration

Changed in version 28, released 2 October 2026. Before version 28, joining the board's Wi-Fi opened a set-up page by itself (the picture above shows it as a "Sign in" page on a phone), and the same page was at 4.3.2.1/admin. From version 28 no page opens by itself and 4.3.2.1/admin shows "Not found". On its own, 4.3.2.1 opens the board's main page, which has no box for your Wi-Fi name and password. Earlier editions of this guide said: If your device states "sign-in required", select this option and go to the sign-in page. If your device does not offer a sign-in page, navigate your browser to "4.3.2.1/admin". They also pointed to a video of these steps made before the change: https://youtu.be/G3ajZazycP4.

Once one board is on your network you never need to do this again: press Share in the Network section of that board's page to bring every other board on the CAN bus onto the same network. The Output-64 picks up Wi-Fi details shared along the cable only when your network name and password are each 19 characters or fewer. If either is longer, use the steps above for the Output-64.

Admin interface

The admin web page is where you change any setting on the board. Each board on the System2 network has its own management web page, unique to that board type and its features.

Admin interface illustration

The Output-64 main page, showing the route and block occupancy example

Output-64 specific fields

The main area has eight columns arranged into four pairs, one pair for each of the four LED outputs. On the left, the numbers 1 to 16 indicate the LED position within the connected string.

  • Columns are labelled BG and FG for background and foreground.
  • The foreground column overrides the background if it is triggered.
  • Setting the BG to a vPort will cause the LED to respond when that vPort is triggered. Note that it will not respond to a stateless push to make, so set the source for toggle switch, stateful or one of the sensor types.
  • When the vPort is triggered the default white colour will be displayed.
  • Setting the foreground vPort will trigger a default red LED and override any background colour when the vPort is set.
  • The background column can be inverted ("Inv"); the foreground cannot.
  • Colours can be selected from the dropdown for both foreground and background. Underneath the vPort configuration you can define up to three custom colours.
  • If colour data is configured from a Panel Controller it will override any colour data set here.

Generic fields

From the main admin page you can see the following information, which is common to all System2 boards:

  • Device name and serial number.
  • Device graphic, which also opens this user guide (from version 27; before that, the product page).
  • User definable text description or location.
  • Show Charts, which plots Wi-Fi signal strength and CAN traffic.
  • Locate Board, which makes the LED on the selected board flash fast to help you find it, and asks every board on the network to report in.
  • Auto CAN ID, which you can override if required.
  • Share and revoke Wi-Fi credentials with all boards on the network.
  • Control buttons, covered in the Actions chapter.
  • A status line showing product name, software version, templates version, IP address, device name and the Wi-Fi network you are connected to.
  • A Protocol button and MQTT broker settings.
  • A status log with a light yellow background, giving a real time commentary: software up to date, boards joining the network, whether you saved your changes, and so on. Each line is timestamped.

New in version 22. The page is in sections you can open and close: Mimic Panel, Lighting Effects, Network and Status Log. The Network section holds the Protocol, CAN and Wi-Fi settings together, with Locate Board next to the CAN address, a HotSpot AutoStart switch, and Share, Revoke and Erase buttons for the Wi-Fi details. Backup and Restore are on the page too, and from version 29 Cloud Backup.

Dashboard charts

Show Charts expands a strip of two small charts above the main grid: the Wi-Fi signal strength the board is seeing, and CAN traffic. They are worth a look when a board is in an awkward spot. A signal that dips regularly is a board that will drop off the network at the worst moment, and moving it 100mm is usually all it takes.

Board location

The board location field, top right, should be used to enter meaningful information to help you locate a specific board. This text is included when boards report in, so it is worth keeping short and specific.

Suggested entry typesB2 Fiddle Yard / 12 Station throat / A3 Scenic
AvoidBaseboard B2 / Main approach on the left

Begin the text with the most meaningful information, such as a baseboard number or location. Reports truncate the location to the first few characters, so "B2" or "C12" is much more useful than the word "Baseboard".

Registering your board

A banner on the main page invites you to register the board. Registration links the board to you, which means a support or warranty enquiry starts with us already knowing what you have and what software it is running. It is optional, the banner can be dismissed, and a registered board can be handed on to a new owner using Change registered owner in the page footer.

Panel Controller V-Ports

RGB configuration

The RGB section requires an RGB output board such as this one.

Each Red, Green or Blue column can have a value from 0 to 255. The Colour column shows the colour of the RGB values entered.

RGB configuration illustration

Background colours are written underneath foreground colours. This allows you to illuminate a route automatically as read from a points position sensor, say in white, and then impose a foreground colour on top from a block occupancy detector.

In the image above you can see physical port 1 is triggering V-Port 1 with a red foreground colour, and physical port 3 is triggering a yellow colour on vPort 3.

The B/G column is used to set a foreground or background colour. For example you could set white on a series of LED vPorts indicating a route, and using a colour setting for a block detector set a red colour as foreground to show occupancy on top of a route display.

Board level configuration

This section is common to all System2 boards, and some examples use the Servo-8 driver.

Locate board

The Locate Board check box causes two actions when selected.

Locate board illustration

First, it makes the flashing LED indicator on that board flash rapidly. This helps locate and identify the board if you have several in one place.

Second, it requests that all CAN connected boards report in with their stats, assigned IP address, CAN ID, board type, name, location and software version.

Locate board illustration

The blue IP address in the status log area is clickable and will take you to the management screen for that board. Any board not connected to Wi-Fi will show an IP address of "0.0.0.0".

Clicking the Locate Board checkbox again removes the tick and stops the rapid flashing. It is also reset by a reboot.

CAN ID management

CAN ID management illustration

The next area down on the main configuration page concerns network parameters.

1Auto CAN ID. Normally left selected (default). This allows the board to assign its own CAN address, and if a duplicate is detected it may automatically move to a vacant address.
2The current board's CAN ID. Shown greyed out if auto is enabled (default).

Automatic range: with Auto CAN ID selected the board draws its own ID and you should not expect it to be persistent, as it can change without notice. System2 is designed with this in mind and the board CAN ID is not relevant to operation.

The CAN specification requires all boards to have a unique CAN ID as part of the collision detection mechanism. Forcing duplicates is a bad idea and will lead to data errors.

CAN ID management illustration

Manual CAN ID selection: we must ask why. There is no benefit we can think of, so it is included for edge cases only. It is not recommended. The manual range is shown on the page next to the field.

When reselecting Auto CAN ID, the current setting remains until a collision is detected, whereupon the software automatically reassigns the ID.

CAN ID management illustration

If a duplicate ID is detected and the address is manually configured, you will see a message in the status log warning of the duplicate address and that automatic change is disabled. You need to reconfigure this yourself.

CAN ID management illustration

With Auto CAN ID enabled the message is slightly different:

CAN ID management illustration

The CAN ID was automatically changed to an unused ID. When the board is rebooted or the web page refreshed, the CAN ID field updates to the new value.

New in version 20. The board now checks its own CAN ID at start up. An ID outside the legal range that CAN itself allows is replaced with a legal one and saved, and the status log records what happened. A board that somehow ended up with an impossible ID no longer sits quietly failing to talk to anything.

Wi-Fi credential sharing

You may recall the procedure to connect the first board to your Wi-Fi network using your phone or tablet. You will be pleased to know that you never have to go through that again. This section covers how to share the Wi-Fi configuration with all boards on your CAN bus.

Connect to a System2 board using your browser. Obviously you will only be able to connect to a board that is already on your local Wi-Fi. Click the "Share WiFi Credentials" button (1).

You will see all boards on the CAN bus reporting in (2) with an IP address. These boards will now be accessible from a web browser on the same Wi-Fi network.

Wi-Fi credential sharing illustration

To revoke Wi-Fi access for all connected boards click "Revoke WiFi Credentials" (1):

Wi-Fi credential sharing illustration

You will see revocation messages in the status log. Each board restarts and shows an IP address of "0.0.0.0", showing that it is not connected to any Wi-Fi network.

The board you are issuing the commands from is not affected and remains connected to Wi-Fi until specifically revoked with Erase WiFi Credentials.

New in version 22. Share WiFi Credentials, Revoke WiFi Credentials and Erase WiFi Credentials are now the Share, Revoke and Erase buttons in the Network section of the page.

The Output-64 picks up Wi-Fi details shared along the cable only when your network name and password are each 19 characters or fewer. If either is longer, give it your Wi-Fi through its own Wi-Fi (see Getting your first board on your Wi-Fi).

Actions

The action area holds the controls covered in this chapter.

New in version 22. Save Changes, Reload Values and Reset to Defaults are proper buttons; the picture below is from an earlier version. The page also has Backup, which writes a dated file of the settings to your computer, and Restore, which puts it back, including the hotspot switch.

Actions illustration

Reset to defaults

This resets most of the board values to defaults. Observe the message in the status log. The default values are live immediately, but will revert to your previous settings on a reboot unless you specifically save them. This is particularly useful for testing and reverting.

Reset to defaults illustration

On the Output-64, resetting to defaults changes the following:

  • Every BG and FG vPort is cleared, and every Inv tick is removed.
  • Colours return to White for background and Red for foreground.
  • The three custom colours return to their factory values.
  • Brightness returns to its default setting.
  • All eight lighting effect slots are emptied, Effects running is on and Full-range effects is off.
  • Auto CAN ID is switched back on.

The following are not changed:

  • Board location description.
  • CAN ID.
  • IP address.
  • Wi-Fi configuration.
  • Registration.

Save changes

As the name suggests, this saves all uncommitted changes to non-volatile memory, to be retained after reboots. After saving you will see the confirmation message in the status log.

Save changes illustration

Reload values

Reload Values resets the parameters to the saved version. This undoes any changes that have not been saved. The browser page refreshes as part of the process.

Erase WiFi credentials

Erasing the Wi-Fi credentials removes the Wi-Fi details and reboots the board you are connected to. This action applies to that board only; other networked boards are unaffected. If you wish to remove all boards from Wi-Fi, see Wi-Fi credential sharing.

Erase WiFi credentials illustration

Update firmware

If your board is connected to your local Wi-Fi and that Wi-Fi has Internet access, you can update the software. When a new version is available a message appears in the status log:

Update firmware illustration

Click Update Firmware to open the Software Update page.

Update firmware illustration

The Software Update page on a board that is up to date

The page shows what has changed since the version you are running, most recent first, with the release dates. If you choose to update you get all the changes right up to the latest version. The update is not mandatory; installation is up to you.

  • Install Latest Update starts the process. It takes about 4 to 8 minutes. Do not power the board off while it runs.
  • View full history shows every release, not only the ones newer than yours.
  • Pre-release channel offers you new versions before they are released generally. Leave it off unless you would like to help test new features.
  • Exit Update returns to the main configuration page without doing anything.

During the update the on-board LED flashes erratically, showing data transfer, and progress is written to the update log. Two files are downloaded: the software itself and the board's web pages. When it is complete the board reboots automatically and rejoins the network.

All your configuration data is preserved across updates.

New in version 28. When the board cannot reach the update server, including just after it is switched on, it keeps the list of releases it last fetched, so the Software Update page is never empty while the main page says an update is available. A board running a newer build than any on its list says so. MegaConsole can also update the board from your PC, offering released software to the boards that need it.

The update fails safe. If the connection is interrupted or the power is lost during an update you can return to the update screen and begin again, although interrupting an update is not recommended.

Roll back firmware

After an update the board keeps the previous version, and the Software Update page offers you two choices for a while:

  • Roll back reverts to the previously installed software. Your settings are preserved and the board reboots within about five seconds. You can upgrade again later from the same page.
  • Lock in permanently dismisses the roll back offer for the version you are running. The next update restores a one-step roll back option.

If you do nothing, the board locks in on its own once it is satisfied the new version is running properly. Roll back is there for the case where a new version does not suit your layout, and it is entirely in your hands.

Reboot

Clicking Reboot restarts the board immediately. You will see a message in the status log that the page will reload automatically after a few seconds, along with a "Please wait ..." in blue. Any unsaved changes are discarded, which is handy if you have made a mess.

Reboot illustration

Reload page

This reloads the web page and resets the status log area. It is useful for clearing the log and confirming you are connected to the board.

Documentation

The User Guide link in the page footer opens this user guide in a new browser window, and so does the picture of the board at the top of the page. Before version 27 both went to the shop's product page. This option requires an Internet connection.

CAN Network Monitor

WARNING: this section may send you to sleep and is not required reading.

The CAN Monitor link takes you to a live view of the traffic on your CAN bus. It should be considered a diagnostic tool, though we relied on it heavily during development. It was rebuilt in software version 18 and is now shared with the rest of the range.

New in version 26. The CAN Monitor page was rebuilt again: messages arrive in a table you can sort by any column and filter down, each described in plain words, the same words MegaConsole uses, and the page keeps listening for as long as you leave it open. The monitor only listens. The description below was written for the earlier page. From the December 2026 update (version 31) the monitor also names the Speed Trap and the Speed Trap V2, and shows their beam and timing messages in plain words.

CAN Network Monitor illustration

The V-Port the packet is intended for is decoded in the right hand column. The headers contain the following:

HeaderDescription
SeqPacket sequence as observed by the board the monitor is running on.
MinNumber of minutes since starting. Rolls over at 99.
SSSeconds within the previous minute.
mSSMilliseconds within the previous second.
uSSMicroseconds within the previous millisecond.
CanIdThe CAN ID that created the packet.
D 0-7Data field of the packet (D0 to D7).
V-PortDecoded V-Port the message is intended for.

The monitor only displays packets created by remote boards. It does not display packets that are transmitted locally. The board running the monitor remains fully operational and responds to events in its usual manner.

In the screenshot above you can see network packets triggered by a button being pushed twice, once to turn on and again to turn off. Under the V-Port column, at minute 17:

V-PortDescription
1An event addressed to V-Port 1 is initiated from CAN ID 493.
161An event is addressed to V-Port 161 from CAN ID 1000 (packet duplicated).
321An event is addressed to V-Port 321 from CAN ID 1000.
161An event is addressed to V-Port 161 from CAN ID 1000 (packet duplicated).

CAN ID 493 is a Panel Controller, and looking at its configuration we see V-Port 1 is a push button attached to physical port 1:

CAN Network Monitor illustration

So we know what created the packet: a button on physical port 1. The next packet was created by CAN ID 1000. Looking at the status log we can see this is a Servo-8 board:

CAN Network Monitor illustration

We are also given the IP address of the board, so clicking the blue IP address takes us to the Servo-8 management portal. The Servo-8 port configuration is reported as:

CAN Network Monitor illustration

The V-Port is 1, meaning channel S1 (servo 1) is listening for this address. Remember this board has a CAN ID of 1000, and it generated a packet to V-Port 161. That is the configured feedback V-Port.

If we look at the packet under column D3 we see a "3" in the data byte. Where is that going?

CAN Network Monitor illustration

The Output Ports section of the Panel Controller matches the feedback V-Port of the Servo-8. It is this port that is listening for the event. The data value of "3" means flash, which causes the Panel Controller to flash the LEDs on physical port 1 to indicate a motor in motion.

When the centre of motion for the servo is reached, another event is triggered to V-Port 321. Looking at the servo port configuration above, the trigger V-Port is configured for 321 and fires when

the servo is at its centre position; particularly useful for firing a frog when the point blades are dead centre.

CAN Network Monitor illustration

Relay R1 is configured for events on V-Port 321 and triggers when the Servo-8 is halfway. This can be freely changed to respond to the same ports as the push button or any other device. It can also provide feedback data of its own; setting the feedback V-Port to "0" disables feedback from the relay.

Finally, the last packet at minute 17 is addressed to V-Port 161 and contains a 0 in the D3 column. That tells the Panel Controller to stop flashing, as the servo has reached its final position.

CAN Network Monitor illustration

At the bottom of the network monitor page are packet statistics. The leftmost column shows the peak and current number of packets per second; the rightmost shows the same data over a one minute interval.

Choosing the protocol: CAN or MQTT

At the bottom of the main page is a Protocol button, with a broker address and port beside it. The Output-64 normally uses the CAN bus, which is what the rest of this guide assumes and what we recommend: it is fast, deterministic and needs no other equipment.

MQTT is offered for layouts already running a broker, typically alongside JMRI. Note that colour override data from a Panel Controller is a CAN feature and is not available over MQTT.

New in version 28. The page shows whether the board is connected to your broker, and the board keeps trying to reconnect, every 30 seconds at most, if the broker restarts or the network drops. MegaConsole can set the broker up on this board with one button, and the board checks that it worked. A broker name ending in .local is found however it is capitalised, and CAN, Native and JMRI modes are strictly one at a time.

MegaConsole has a broker of its own. If you choose Over WiFi (wireless) in its Start here, the boards talk through MegaConsole's broker on that PC, which must then stay on. With Along the cable (wired) the layout works with the PC off.

Status area

The status area shows information at the board level and is display only.

Status area illustration
  • Board type. In this case a Servo-8; on your board it will read Output-64.
  • S/W Rev: the current software version loaded.
  • Templates: the version of the loaded web pages. Normally this matches the software version above.
  • IP Address: the current address of the board as allocated by your Wi-Fi.
  • Name: the board name and serial number. Each is unique and is a combination of the board type and the last three hexadecimal digits of the MAC address.
  • SSID: the network name of the configured Wi-Fi network.

A PRE-RELEASE badge appears next to the status log heading if the board is running a pre-release build.

Recovering a board

If a board ever ends up with software that will not run properly, it can fetch a known good copy for itself.

  • Remove power from the board.
  • Hold the HOTSPOT button down and re-apply power, keeping the button held.
  • Keep holding for at least 10 seconds. The RUN LED begins to flash rapidly to confirm that recovery is armed. Release the button.
  • The board connects to Wi-Fi, downloads a recovery image and installs it. Leave it powered until it has finished and rebooted.

Recovery needs the board to have working Wi-Fi credentials and an Internet connection, because it fetches the recovery image from us. It is not a downgrade tool: it installs a known good version, not the version you were running before. To go back one version deliberately, use Roll back firmware instead.

Holding the button for 1 to 10 seconds starts the Wi-Fi hotspot instead, which is the normal way to give a board new Wi-Fi details. Only a hold of 10 seconds or more at power-on enters recovery.

The storage upgrade

Software version 20 performs a one-off reorganisation of the way the board stores its software inside. It makes room for everything that has been added and everything still to come, and it uses a filesystem that copes better with power cuts and repeated writes.

There is nothing for you to configure. Choose the update in the normal way and the board does the rest.

  • It takes a few minutes and the board restarts several times along the way.
  • Keep it powered on until it has finished.
  • Your settings, including your panel configuration and your effect slots, are preserved.
  • It only happens once. Afterwards updates are the ordinary kind again.

In conclusion

We hope you will agree that System2 Air is a powerful, flexible model railway control system. Future updating is baked in through a trivial update process, and new boards are under development to expand the range further.

If you have made it this far through the user reference then you will understand just how much this board is capable of. Sixty-four LEDs is a great many, and between the mimic panel display and sixteen scenic effects there is very little on a layout that this board cannot light.

Happy railroading!

Appendix A: Software release notes

The releases since version 20 come first, newest first, followed by the original notes for versions 16 to 20.

Coming in the December 2026 update - Version 31 (on test now)

Planned for 1 December 2026. It is on test on MegaConsole's early channel now.

  • The board takes your layout's time zone from MegaConsole, or from another board on the System2 cable, and keeps it, so its dusk-to-dawn lamps and the times in its log follow local time without anyone opening its page first. A time zone set on the board's own page still wins. A board with no internet takes the time of day from another board on the cable that has it, or from MegaConsole.
  • If the board's Wi-Fi stops answering, it restarts its Wi-Fi and is back on your network within about a minute. Before, a new board appearing on the layout at that moment could leave it off your network for several minutes.
  • MegaConsole can ask the board what it is able to do and what each output is set to right now, so a MegaConsole started after the layout can show it as it is without waiting for something to move. MegaConsole uses this as its own releases add it.
  • The CAN Monitor page names the Speed Trap and the Speed Trap V2, and shows their beam and timing messages in plain words.

Version 30 - 31 October 2026

  • Needs far less memory, so its web page can no longer make it stop answering, and gets back on your network and MQTT broker by itself.
  • New: cloud backup (see version 29).
  • After updating, open its web page once so it takes your time zone. Until then, its dusk-to-dawn lamps stay on all the time.
  • If this update will not go on, switch the board off and on, keep its page closed and try again straight away.

Version 29 - 16 October 2026

  • Cloud backup: Backup Now, an automatic copy after every Save or update, and restore from any of your cloud copies.
  • The automatic copy is sent by the board's page or by MegaConsole, whichever is running. The board itself never needs the internet for it.
  • Backup, Backup Now, the automatic cloud copy and MegaConsole's own backups all take the same settings file.
  • A restore restarts the board only when the restored settings need it, and a damaged backup file is refused rather than half applied.

Version 28 - 2 October 2026

  • A brand-new board lights its LEDs straight away: LEDs 1 to 64 follow V-Ports 1 to 64, output 1's sixteen LEDs first. Boards already set up keep their settings.
  • Joining the board's own Wi-Fi no longer opens a page by itself. The Wi-Fi set-up page is at 4.3.2.1/wifimanager.html (see Getting your first board on your Wi-Fi).
  • The board shows whether it is connected to your MQTT broker and keeps trying to reconnect, every 30 seconds at most. MegaConsole can set the broker up with one button, a broker name ending in .local is found however it is capitalised, and CAN, Native and JMRI modes are strictly one at a time.
  • When the board cannot reach the update server, it keeps the list of releases it last fetched, and a board running a newer build than any on its list says so.

Version 27 - 8 September 2026

  • The four LED strips are sent one after another, so all four outputs light. With version 26 the start-up rainbow showed on output 2 alone on our bench board, and a mimic panel wired to the other outputs never lit.
  • A point or signal that is on the move flashes its cell until it arrives, and stops after ten seconds if the arrival is never reported.
  • Clicking the picture of the board at the top of its web page opens this user guide, as do the User Guide links on the main page and the update page.
  • The photo and logo on the board's web page are much smaller files, so the page loads reliably on a busy layout.

Version 26 - 31 August 2026

  • Plug a programming lead in and MegaConsole shows which board is on the end of it, under the COM port.
  • MegaConsole can ask one board on the bus who it is. It answers with the serial number set into its chip when it was made, the software it is running and whether it is on your Wi-Fi.
  • The CAN Monitor page is rebuilt: messages arrive in a table you can sort by any column and filter, each described in plain words, and the page keeps listening for as long as you leave it open.

Version 25 - 20 August 2026

  • A new or erased board raises its own set-up Wi-Fi straight away. Before, it spent about two minutes trying to join a network that was not yours first.
  • After a firmware update the board still restores the network details it had, so an update does not send you back to its own Wi-Fi.
  • A console watching the board no longer pauses the board's own work while it reads the health figures.

Version 23 - 19 August 2026

  • The early-access build, marked as the stable one for MegaConsole. A message the MegaPoints service refuses is reported as refused, and a health report too big to send is announced instead of being dropped.

Version 22 - 15 August 2026

  • The board starts its own Wi-Fi when it cannot reach your network: straight away if it has never been given one, otherwise after two minutes. It keeps trying your network once a minute and takes its own Wi-Fi down again once your network answers and nobody is using it. The HotSpot AutoStart switch in the Network section turns this off.
  • The main page is rebuilt in sections you can open and close: Mimic Panel, Lighting Effects, Network and Status Log. The Network section holds Protocol, CAN and Wi-Fi settings, with Locate Board next to the CAN address.
  • Save Changes, Reload Values and Reset to Defaults are proper buttons, the Wi-Fi controls are Share, Revoke and Erase buttons, and Backup and Restore are on the page.
  • The board no longer restarts itself when it loses Wi-Fi while it is running.

Version 21 - 14 August 2026

  • MegaConsole can restart the board over the network, instead of someone switching it off and on. A restart is refused while a firmware update is downloading or waiting to be confirmed.

Version 20 - 12 August 2026

A required one-time storage upgrade that makes room for all future features and updates. It reorganises the way your Output-64 stores its software inside, then installs the newest version by itself. Your settings are preserved. It takes a few minutes and restarts several times on the way; please keep it powered on until it finishes.

This version also repairs an out of range CAN ID at start up and saves the corrected value.

Version 19 - 11 August 2026

Stability enhancements. The board's own web pages now load reliably every time. Before this release a page could stop part way through loading, and if that happened often enough the board could stop responding altogether until it was switched off and on again. The update page was where you were most likely to notice it: the page looked perfectly normal, but the release history below was empty.

Version 18 - 11 August 2026

Production release for the RGB LED Panel Driver: the fleet-standard storage layout, the shared update system with roll back and a pre-release channel, dashboard charts, product registration, settings backup and restore, and a rebuilt CAN Network Monitor.

Version 17 - 10 August 2026

The board's name now shows on other boards. An Output-64 announcing itself used to appear on other boards' status logs as a bare IP address while every other product showed its name; it now answers with its name and location. Every lighting effects field gained an explanation you can hover over.

Version 16 - 10 August 2026

The first over-the-air release for this product, and the one that introduced scenic lighting effects: sixteen effects across eight slots, layered on top of the mimic panel display. Each slot picks a channel, a run of LEDs, brightness, speed and depth, and can override the effect's colours. Also CAN self-recovery and a secure connection memory fix.

Making life easier

Use the device name to connect

During the initial connection you probably used the board's IP address. IP addresses are numeric and not very meaningful. Each device has a name printed on the label on the top of the PCB.

Use the device name to connect illustration

If the label reads "out64-73f0ce", type "http://out64-73f0ce.local" into your browser's address bar, not the search bar, and your network should locate the device for you. You will not need to enter the IP address again. Substitute your own device name and serial number.

Use share Wi-Fi credentials for all other boards

Once you have one board connected to your network, use Share WiFi Credentials to bring all connected boards onto your Wi-Fi.

Use share Wi-Fi credentials for all other boards illustration

Use Revoke WiFi Credentials to remove boards from your Wi-Fi. We use these options all the time, so you only need one central admin board connected to your network until it suits you to add more.

Bookmark your devices

Instead of manually maintaining a list of your boards' network names, create a bookmark folder in your browser and add all the device names to it.

Name your effect slots and your board

Eight effect slots and a shelf of boards all look the same a month later. Fill in the Location field and give every effect slot a name. It costs nothing now and saves real time when something needs changing mid-exhibition.

Contacting us

Web megapointscontrollers.co.uk
Email info@megapointscontrollers.com

If you have any product improvement suggestions we would be very pleased to hear from you.

All parts (c) MegaPoints Controllers 2026.

NOTE: We operate a policy of continuous improvement. Colours, specifications and even the placement of components may vary from time to time.